Autonomy list |
|
Autonomy & recycle speed of flash
units tested with: |
|
- Flash Feeder COMPACT with 1 ×
Compact Battery Case |
|
|
|
|
|
|
|
Flash Feeder COMPACT with 1 × Compact
Battery Case |
|
Flash Type/Model |
Flash Brand |
Flash Power |
FlashFeeder version |
Recycle time |
Autonomy (Full Power) |
|
|
Nominal (Ws =J) |
EU/USA/JPN |
(seconds) |
(N° of flashes) |
|
Yellow Cube 800i |
Briese |
800 |
EU - 230V/50Hz |
2,5 |
276 |
|
Yellow Cube 800i |
Briese |
800 |
USA - 115V/60Hz |
2,0 |
650 |
|
2 × Espirit 500 |
Bowens |
2×500=1000 |
EU - 230V/50Hz |
1,7 |
449 |
|
D1 1000 |
Profoto |
1000 |
EU - 230V/50Hz |
1,3 |
681 |
|
2 x Style 600 RX |
Elinchrom |
2x600=1200 |
EU - 230V/50Hz |
1,5 |
621 |
|
Style 1200 RX |
Elinchrom |
1200 |
EU - 230V/50Hz |
2,0 |
630 |
|
Digital 1200 RX |
Elinchrom |
1200 |
EU - 230V/50Hz |
2,5 |
300 |
|
Compact 1200R |
Profoto |
1200 |
EU - 230V/50Hz |
1,5 |
588 |
|
Pro-7a |
Profoto |
1200 |
EU - 230V/50Hz |
1,5 |
387 |
|
Pro-7s |
Profoto |
1200 |
EU - 230V/50Hz |
1,5 |
387 |
|
2 x Classic 750 |
Balcar |
2x750=1500 |
EU - 230V/50Hz |
2,8 |
563 |
|
Nova B 1500 S |
Hensel |
1500 |
EU - 230V/50Hz |
3,0 |
348 |
|
Jet System 1600 |
Balcar |
1600 |
EU - 230V/50Hz |
5,0 |
284 |
|
3 x Style 600 RX |
Elinchrom |
3x600=1800 |
EU - 230V/50Hz |
2,5 |
366 |
|
T2 - 2400 |
Balcar |
2400 |
EU - 230V/50Hz |
3,5 |
283 |
|
2 x Style 1200 RX |
Elinchrom |
2x1200=2400 |
EU - 230V/50Hz |
3,5 |
271 |
|
Chic 2 speed |
Elinchrom |
2400 |
EU - 230V/50Hz |
4,0 |
132 |
|
Digital 2400 RX |
Elinchrom |
2400 |
EU - 230V/50Hz |
4,9 |
150 |
|
Acute 2 2400 |
Profoto |
2400 |
EU - 230V/50Hz |
3,7 |
216 |
|
D4 - 2400 |
Profoto |
2400 |
USA - 115V/60Hz |
4,0 |
155 |
|
D4 - 2400 |
Profoto |
2400 |
EU - 230V/50Hz |
4,0 |
136 |
|
Pro - 8a 2400 air |
Profoto |
2400 |
EU - 230V/50Hz |
3,5 |
194 |
|
Pro-7a |
Profoto |
2400 |
USA - 115V/60Hz |
3,5 |
205 |
|
Pro-7a |
Profoto |
2400 |
EU - 230V/50Hz |
3,5 |
198 |
|
Pro-7s |
Profoto |
2400 |
USA - 115V/60Hz |
3,5 |
205 |
|
Pro-7s |
Profoto |
2400 |
EU - 230V/50Hz |
3,5 |
198 |
|
The above figures are for orientation only and
may vary in practice due to several reasons. (For additional
information contact ELEKTRONA) |
|
|
|
|
|
|
|
All flashes were testsed at full flash power.
Modeling lamps were switched off. |
|
|
|
|
|
|
|
The testing procedure includes the use of the
"additional energy" procedure (see 2. and 3. bellow), which extends
autonomy for additional: |
|
7 - 25% (typically 15%) with FlashFeeder COMPACT
connected to one Compact Battery Case (more additional cases can be
connected in chain) |
|
(Unlimited number of additional Battery Cases can
be connected in chain) |